Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Wave spectrum input fields (Gamma, Sigma, Random seed) are now correctly greyed out depending on selection (ANYM 142)
  • When using a wave train, the keywords Hs, Tp and Wave seed will not be written to ini-file (ANYM 142)
  • The error "Failed to find the native call to the mooringline calculation" has been fixed (ANYM 344)
  • When using a wave train a warning message is shown when the wave train sample time is not a equal or a multiple of the simulation time step (ANYM 330)
  • When a wave train is shorter than the simulation a clear error message is shown and the simulation won't start
  • For regular waves the random seed need not be set, the wrapper fills in a 1 because it is compulsory in aNySim (ANYM 336)
  • In the tab "Signal selection" the Min and Max values are now actually used, in previous versions only the default values were used (ANYM 349)
  • Minor database corrections when opening a new project (does not affect calculations)
  • When using an irragular wave in combination with Aranha damping, the Aranha demping is switch off. User is notified
  • When using an irrular wave as first wave input, the second wave input (swell) is disabled
  • When wave parameters are entered which are outside the permitted range, the user is notified

aNyMoor v1.2.3 release date is soon.

...